What Is a Facade Inspection (NYC Local Law 11 / FISP)?

New York City requires owners of buildings taller than six stories to have exterior walls inspected every five years under the Facade Inspection Safety Program (FISP), commonly called Local Law 11. Reports are filed with the Department of Buildings and classify each facade as Safe, SWARMP or Unsafe.

Which buildings and when

FISP applies to buildings greater than six stories in New York City. Its legal basis is Article 302 of the NYC Administrative Code and the DOB rule 1 RCNY 103-04. The program grew from Local Law 10 of 1980 and Local Law 11 of 1998.

Inspections run in five-year cycles. Cycle 10 runs from February 21, 2025 to February 21, 2030 and is split into three filing sub-cycles by the last digit of the tax block number: 10A (blocks ending in 4, 5, 6 or 9) from February 21, 2025 to February 21, 2027; 10B (0, 7 or 8) from February 21, 2026 to February 21, 2028; and 10C (1, 2 or 3) from February 21, 2027 to February 21, 2029. Confirm your building's window on the DOB website.

Who inspects and how

The inspection must be performed by a Qualified Exterior Wall Inspector (QEWI): a New York State licensed Professional Engineer or Registered Architect with relevant experience who is approved by DOB. The QEWI examines all facades, with close-up (hands-on) inspection from scaffolding or rope access at intervals along facades facing a public right of way, typically no more than 60 ft apart, and documents conditions with photographs and mapping.

The QEWI also inspects appurtenances such as balcony railings, fire escapes, parapets, air conditioner brackets and decorative elements.

Report ratings and what happens next

Each condition is classified as Safe, SWARMP (Safe With A Repair and Maintenance Program, meaning repairs are needed within the cycle) or Unsafe. Unsafe conditions require immediate public protection, typically a sidewalk shed, notification to DOB and repairs, followed by an amended report.

Late filings and uncorrected unsafe conditions carry civil penalties, and penalties for long-standing sidewalk sheds have increased under recent rules. Starting early in the sub-cycle leaves time for scaffold permits and repairs.

Frequently asked questions

Can drones be used for FISP?

DOB does not accept drone imagery in place of the required close-up inspection, though it can supplement it.

What does SWARMP mean?

Safe With A Repair and Maintenance Program. The facade is not currently unsafe but needs repairs within the cycle or it may become unsafe.

Does Local Law 11 apply to buildings of six stories or less?

No. FISP covers buildings greater than six stories, though owners of all buildings must maintain facades in a safe condition.

Sources

  • NYC Department of Buildings, Facade Inspection Safety Program (FISP)
  • 1 RCNY 103-04, Periodic Inspection of Exterior Walls and Appurtenances of Buildings
  • NYC Administrative Code Article 302, Maintenance of Exterior Walls

Have a project? Get a free quote.

Tell us what you need. We reply with scope, fee and schedule, including review by a PE licensed in your state.

Get a free quote