Septic Perc Test Explained
A perc test measures how fast water soaks into the soil so a septic drainfield can be sized. Many states now use soil profile evaluations in addition to or instead of the classic perc test.
How a perc test works
Test holes are dug in the proposed drainfield area, usually to the depth of the planned trenches. The holes are pre-soaked so the soil is saturated, then the tester fills them with water and measures how far the level drops over set intervals. The result is a percolation rate in minutes per inch.
Soils that are too fast (coarse sand and gravel) may not treat wastewater before it reaches groundwater; soils that are too slow (dense clay) cannot absorb it. Many codes accept rates roughly between 1 and 60 minutes per inch for conventional systems, with exact limits set by state rules.
Soil evaluations
Many health departments require a soil profile evaluation in test pits by a soil scientist, engineer or licensed evaluator. They look at soil texture, structure and color, especially mottling that shows seasonal high groundwater, and depth to bedrock or restrictive layers. Required vertical separation to groundwater and rock is a key design limit.
The NRCS Web Soil Survey gives a free preliminary look at mapped soils and their limitations for septic absorption fields, but site testing is still required for a permit because soils vary over short distances.
What the results mean
The perc rate and soil findings set the drainfield size and system type. Good soils allow a conventional gravity system. Slow soils, shallow groundwater or rock may require larger fields, mound systems, pressure distribution or advanced treatment units, which cost more.
If a lot fails, options may include testing other areas, alternative systems approved by the state, or connection to public sewer. Buyers of rural land often make the purchase contingent on a successful perc test.
Frequently asked questions
When can a perc test be done?
Some states restrict testing to the wet season so results reflect high groundwater. Check with the county health department.
Who designs the septic system after the test?
Depending on the state, a licensed engineer, an onsite system designer or a registered sanitarian.
How long are perc test results valid?
It varies by jurisdiction. Some accept results for years; others require retesting if plans change.
Sources
- U.S. EPA, Onsite Wastewater Treatment Systems Manual (EPA/625/R-00/008, 2002)
- U.S. EPA SepticSmart program
- USDA NRCS Web Soil Survey
Have a project? Get a free quote.
Tell us what you need. We reply with scope, fee and schedule, including review by a PE licensed in your state.