Structural
Wind Velocity Pressure Calculator (ASCE 7)
Wind design in the US starts with the velocity pressure qz from ASCE 7. Enter the basic wind speed from the ASCE 7 maps or the ASCE Hazard Tool and the site factors. For estimation only; a licensed PE must design.
Formula
ASCE 7-16 Eq. 26.10-1: qz = 0.00256 × Kz × Kzt × Kd × Ke × V² (psf, V in mph). ASCE 7-22 moves Kd out of qz into the pressure equations, but the product is the same. External pressure on the windward wall = qz × G × Cp, with G = 0.85 for rigid buildings and Cp = 0.8. Internal pressure (GCpi) and leeward and roof pressures are separate.
Worked example
V = 115 mph, Exposure C at 15 ft (Kz = 0.85), flat terrain (Kzt = 1.0), Kd = 0.85, Ke = 1.0: qz = 0.00256 × 0.85 × 1.0 × 0.85 × 1.0 × 115² = 24.46 psf. Windward external pressure = 24.46 × 0.85 × 0.8 = 16.63 psf.
Assumptions and limits
- Kz = 0.85 corresponds to Exposure C at 0 to 15 ft; Exposure B at 0 to 30 ft is 0.70 (ASCE 7 Table 26.10-1).
- V is the strength-level basic wind speed for the building's Risk Category.
- Does not combine internal pressure, leeward suction, roof uplift or components and cladding pressures.
- For estimation only. A licensed Professional Engineer (PE) must design and stamp any structural, foundation or life-safety element.
Frequently asked questions
Where do I find the design wind speed?
From the ASCE 7 wind maps for the building's Risk Category, most easily through the free ASCE Hazard Tool (ascehazardtool.org), or from the local building department.
What are Exposure B, C and D?
B is urban and suburban terrain with closely spaced obstructions, C is open terrain with scattered obstructions, and D is flat unobstructed areas and water surfaces in hurricane-prone or shoreline areas. Exposure changes Kz.
Why is wind pressure proportional to speed squared?
Velocity pressure is the kinetic energy of moving air, ½ρV². The 0.00256 constant converts air density and mph to psf.
Sources
- ASCE/SEI 7-22, Chapter 26, Wind Loads: General Requirements
- ASCE/SEI 7-16, Equation 26.10-1 and Table 26.10-1
- ASCE Hazard Tool, ascehazardtool.org