Wisconsin

Soil Percolation (Perc) Test

Perc and deep hole soil testing to determine whether land can support a septic system, and what type.

Typical US fee$200 to $3,000
Typical timeline1 to 4 weeks, seasonal in some states
Licensing boardWisconsin Examining Board of Architects, Landscape Architects, Professional Engineers, Designers and Professional Land Surveyors

What the work involves

A percolation test measures how fast water drains into soil; many jurisdictions also require deep hole test pits to inspect soil layers and the seasonal high water table. Tests may be performed by a septic contractor, soil scientist or engineer, often witnessed by the health department. Results determine whether a lot is buildable without sewer and what septic system it needs.

Local conditions we plan for

  • Deep frost penetration
  • Heavy snow loads
  • Great Lakes shoreline erosion
  • Karst in the southwest Driftless Area and Door County

Building code: IBC 2021 statewide for commercial buildings; one and two family dwellings use the state Uniform Dwelling Code instead of the IRC (ICC adoption chart, April 2026).

When you need it

  • Buying land without public sewer
  • Applying for a septic permit
  • Planning a lot split
  • Replacing a failed septic system

Frequently asked questions

How much does soil Percolation (Perc) Test cost?

Across the US, soil Percolation (Perc) Test usually costs $200 to $3,000 per test. HomeGuide reports $200 to $1,500 for hand-dug tests and $500 to $3,000 or more for excavator tests; HomeAdvisor gives $750 to $1,900 (average $1,300). An engineer adds $200 to $500 per HomeGuide.

How long does soil Percolation (Perc) Test take?

Plan on 1 to 4 weeks, seasonal in some states from signed proposal to stamped deliverables, longer if a site visit, soil testing or a permit review cycle is involved.

Do I need a licensed PE for soil Percolation (Perc) Test?

In most US jurisdictions, yes. When the work needs a permit, the plans, calculations or report usually must be sealed by a Professional Engineer licensed in the state where the project is located. Anything we prepare for permit goes to a PE licensed in that state, who reviews and seals it before you submit.

How do I verify an engineer's license in Wisconsin?

Engineers practicing in Wisconsin are licensed by the Wisconsin Examining Board of Architects, Landscape Architects, Professional Engineers, Designers and Professional Land Surveyors. You can confirm a license number and its status in the board's public license search before you sign a contract.

How deep is the frost line in Wisconsin?

Wisconsin Uniform Dwelling Code SPS 321.16 requires footings to be below frost penetration or at least 48 inches below adjacent grade, whichever is deeper (one and two family dwellings). Local building departments set the required footing depth, so confirm the exact figure for your county before designing foundations or retaining walls.

Which building code applies in Wisconsin?

IBC 2021 statewide for commercial buildings; one and two family dwellings use the state Uniform Dwelling Code instead of the IRC (ICC adoption chart, April 2026). Cities and counties can add local amendments, which is one reason to hire an engineer who works in your area.

Cities we serve

Full service details →   State requirements →